Labconco CentriVa DNA Systems 7970037 User Manual

Browse online or download User Manual for Accessories for air Labconco CentriVa DNA Systems 7970037. Labconco CentriVa DNA Systems 7970037 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 36
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Please read the User’s Manual before operating equipment.
CentriVap
®
DNA Systems
Models
7970010
7970011
7970030
7970035
7970037
Labconco Corporation
8811 Prospect Avenue
Kansas City, MO 64132-2696
800-821-5525, 816-333-8811
FAX 816-363-0130
HOME PAGE www.labconco.com
U
U
s
s
e
e
r
r
s
s
M
M
a
a
n
n
u
u
a
a
l
l
To receive important product updates,
complete your product registration card
online at register.labconco.com
Page view 0
1 2 3 4 5 6 ... 35 36

Summary of Contents

Page 1 - DNA Systems

Please read the User’s Manual before operating equipment. CentriVap®DNA Systems Models 7970010 7970011 7

Page 2 - ECO H435

Chapter 3: Getting Started Product Service 1-800-522-7658 6 Unpacking Your CentriVap Carefully unpack your CentriVap and inspect it for damage that

Page 3

Chapter 3: Getting Started Product Service 1-800-522-7658 7Setting Up Your CentriVap After you verify receipt of the proper components, move your Cen

Page 4

Chapter 3: Getting Started Product Service 1-800-522-7658 8 Chemical Resistance of CentriVap Components Your CentriVap DNA Centrifugal Concentrator

Page 5

Chapter 3: Getting Started Product Service 1-800-522-7658 9When using compounds in the CentriVap that are hostile to the materials of construction, i

Page 6 - Safety Symbols

Chapter 3: Getting Started Product Service 1-800-522-7658 10 CAUTION: Solvents used in the CentriVap may be flammable or hazardous. Use extreme cau

Page 7 - Electrical Requirements

Product Service 1-800-522-7658 11 CChhaapptteerr 44:: UUssiinngg YYoouurr CCeennttrriiVVaapp After your CentriVap has been installed as

Page 8 - Space Requirements

Chapter 4: Using Your CentriVap Product Service 1-800-522-7658 12 Planning Thoroughly understand procedures and the equipment operation prior to beg

Page 9

Chapter 4: Using Your CentriVap Product Service 1-800-522-7658 13 The tables in Appendix C: CentriVap Specifications indicate approximate times requi

Page 10 - CentriVap Components

Chapter 4: Using Your CentriVap Product Service 1-800-522-7658 14 Operating the CentriVap Controls Preheat: To preheat the chamber, press the “PREHE

Page 11 - Setting Up Your CentriVap

Chapter 4: Using Your CentriVap Product Service 1-800-522-7658 15 To reset the timers to the original set point time when running programs other than

Page 12 - Components

Copyright © 2009, 2012, 2013 Labconco Corporation. All rights reserved. The information contained in this manual and the accompanying products are

Page 13 - Solvent Safety Precautions

Chapter 4: Using Your CentriVap Product Service 1-800-522-7658 16 10. Press “STOP” to terminate operation if the CentriVap has not already stopped i

Page 14

Chapter 4: Using Your CentriVap Product Service 1-800-522-7658 17 Safety Precautions Special precautions must be observed if the materials used in

Page 15

Product Service 1-800-522-7658 18 CChhaapptteerr 55:: MMaaiinnttaaiinniinngg YYoouurr CCeennttrriiVVaapp Under normal operation, the Ce

Page 16 - Glassware Selection

Chapter 6: Accessories for Your CentriVap Product Service 1-800-522-7658 19Daily: 1. To prolong the life of the DNA vacuum pump and to optimize its

Page 17 - CentriVap Controls

Product Service 1-800-522-7658 20 CChhaapptteerr 66:: AAcccceessssoorriieess ffoorr YYoouurr CCeennttrriiVVaapp The configuration of y

Page 18

Chapter 6: Accessories for Your CentriVap Product Service 1-800-522-7658 21The following accessories are available for the CentriVap DNA Concentrator

Page 19 - Operating the CentriVap

Chapter 6: Accessories for Your CentriVap Product Service 1-800-522-7658 22 Installing a Glass Lid Turn off the CentriVap. Unplug the power cord fr

Page 20 - Gas Ballast

Chapter 6: Accessories for Your CentriVap Product Service 1-800-522-7658 23 Be sure to use the proper cartridge for your application. The moisture c

Page 21 - Safety Precautions

Chapter 6: Accessories for Your CentriVap Product Service 1-800-522-7658 24 Installing a CentriZap™ Strobe Light An accessory strobe light is availa

Page 22

Product Service 1-800-522-7658 25 CChhaapptteerr 77:: TTrroouubblleesshhoooottiinngg Refer to the following if your CentriVap fails to ope

Page 23

TTAABBLLEE OOFF CCOONNTTEENNTTSS CHAPTER 1: INTRODUCTION 1 Safety Symbols 2 CHAPTER 2: PREREQUISITES 3 Electrical

Page 24

Chapter 7: Troubleshooting Product Service 1-800-522-7658 26 Other corrective actions for potential problems are as follows: PROBLEM CAUSE CORREC

Page 25

Product Service 1-800-522-7658 27 AAppppeennddiixx AA:: CCeennttrriiVVaapp CCoommppoonneennttss The following pages list components that

Page 26 - Installing a Glass Lid

Appendix A: CentriVap Components Product Service 1-800-522-7658 28

Page 27 - Installing a Vacuum Gauge

Product Service 1-800-522-7658 29 AAppppeennddiixx BB:: CCeennttrriiVVaapp DDiimmeennssiioonnss

Page 28

Product Service 1-800-522-7658 30 AAppppeennddiixx CC:: CCeennttrriiVVaapp SSppeecciiffiiccaattiioonnss This Appendix contains technical

Page 29

Appendix C: CentriVap Specifications Product Service 1-800-522-7658 31 Evaporation Rates Solvent Tube Size (ml) Number of Samples Sample Size (ml) T

Page 30

Product Service 1-800-522-7658 32

Page 31

CHAPTER 6: ACCESSORIES FOR YOUR CENTRIVAP 20 Installing a Glass Lid 22 Installing a Secondary Chemical Trap 22 Installing a Vacuum Gaug

Page 32

Product Service 1-800-522-7658 1 CChhaapptteerr 11:: IInnttrroodduuccttiioonn Congratulations on your purchase of a Labconco CentriVap DNA

Page 33

Chapter 1: Introduction Product Service 1-800-522-7658 2 Safety Symbols Your CentriVap Concentrator was designed with safety in mind, however conditi

Page 34

Product Service 1-800-522-7658 3 CChhaapptteerr 22:: PPrreerreeqquuiissiitteess Before you install your CentriVap, you need to prepare you

Page 35 - Evaporation Rates

Chapter 2: Prerequisites Product Service 1-800-522-7658 4 Location and Exhaust Requirements The CentriVap Concentrator should be located on a surface

Page 36

Product Service 1-800-522-7658 5 CChhaapptteerr 33:: GGeettttiinngg SSttaarrtteedd Now that the site for your CentriVap is properly prepa