User’s Manual
Protector
®
Premier
®
Laboratory Fume Hoods
Models
10040 Series
10050 Series
10060 Series
10080 Series
Please read the User’s Manual before operating the equipment.
Page view 0
1 2 3 4 5 6 ... 58 59

Summary of Contents

Page 1 - User’s Manual

Original instructions Labconco Corporation 8811 Prospect Avenue Kansas City, MO 64132-2696 800-821-5525, 816-333-8811 FAX 816-363-0130 E-MAIL labconc

Page 2 - Warranty

Chapter 2: Prerequisites Product Service 1-800-522-7658 6 Original instructions Location Requirements The fume hood should be located away from traf

Page 3 - TABLE OF CONTENTS

Chapter 2: Prerequisites Product Service 1-800-522-7658 7 Original instructions Proper blower selection can be determined from these exhaust requ

Page 4

Chapter 2: Prerequisites Product Service 1-800-522-7658 8 Original instructions également mis fin à la boîte de jonction point de câblage unique pour

Page 5 - INTRODUCTION

Product Service 1-800-522-7658 9 Original instructions CHAPTER 3 GETTING STARTED Now that the site for your laboratory fume hood is properly

Page 6 - About This Manual

Chapter 3: Getting Started Product Service 1-800-522-7658 10 Original instructions Unpacking Your Fume Hood Carefully remove the shrink-wrap or cart

Page 7 - Typographical Conventions

Chapter 3: Getting Started Product Service 1-800-522-7658 11 Original instructions Sash Weight Release To protect the fume hood from damage in shipme

Page 8 - Your Next Step

Chapter 3: Getting Started Product Service 1-800-522-7658 12 Original instructions The following are instructions for mounting a cross support: 1.

Page 9 - CHAPTER 2

Chapter 3: Getting Started Product Service 1-800-522-7658 13 Original instructions Connecting to the Hood Exhaust System WARNING: The weight of the

Page 10 - Exhaust Requirements

Chapter 3: Getting Started Product Service 1-800-522-7658 14 Original instructions WARNING: The building electrical supply system for Protector Hood

Page 11 - Electrical Requirements

Chapter 3: Getting Started Product Service 1-800-522-7658 15 Original instructions Figure 3-2 All wiring for the fume hood SHOULD be performed by

Page 12 - Space Requirements

Copyright © 2012, 2014 Labconco Corporation. All rights reserved. The information contained in this manual and the accompanying products are copyrig

Page 13 - GETTING STARTED

Chapter 3: Getting Started Product Service 1-800-522-7658 16 Original instructions The fluorescent light has been mounted outside the top liner pane

Page 14 - Unpacking Your Fume Hood

Chapter 3: Getting Started Product Service 1-800-522-7658 17 Original instructions CAUTION: Natural gas should be used only in the service fixture

Page 15 - Structure and Work Surface

Product Service 1-800-522-7658 18 Original instructions CHAPTER 4 PERFORMANCE FEATURES AND SAFETY PRECAUTIONS Performance Features: The Pr

Page 16

Chapter 4: Performance Features & Safety Precautions Product Service 1-800-522-7658 19 Original instructions 6. Lift-Away™ front panel provides

Page 17 - Original instructions

Chapter 4: Performance Features & Safety Precautions Product Service 1-800-522-7658 20 Original instructions 17 7 19

Page 18

Chapter 4: Performance Features & Safety Precautions Product Service 1-800-522-7658 21 Original instructions See Diagram on Page 20. 22. CAUTIO

Page 19 - Internal Junction

Chapter 4: Performance Features & Safety Precautions Product Service 1-800-522-7658 22 Original instructions WORK SURFACE. INSTEAD, ELEVATE THE

Page 20 - Protector Fume Hood

Chapter 4: Performance Features & Safety Precautions Product Service 1-800-522-7658 23 Original instructions Perchloric acid use in this hood is

Page 21 - Surface

Chapter 4: Performance Features & Safety Precautions Product Service 1-800-522-7658 24 Original instructions Proper operation of the fume hood de

Page 22 - AND SAFETY PRECAUTIONS

Product Service 1-800-522-7658 25 Original instructions CHAPTER 5 USING YOUR PROTECTOR PREMIER Operating the Vertical-Rising Sash Because of

Page 23

Original instructions TABLE OF CONTENTS CHAPTER 1: INTRODUCTION 1 About This Manual 2 Typographical Conventions

Page 24

Chapter 5: Using Your Protector Premier Product Service 1-800-522-7658 26 Original instructions Operating the Lights Your Protector Fume Hood utilize

Page 25 - Safety Precautions

Chapter 5: Using Your Protector Premier Product Service 1-800-522-7658 27 Original instructions Unloading Materials and Equipment  Objects in conta

Page 26

Product Service 1-800-522-7658 28 Original instructions CHAPTER 6 MAINTAINING YOUR PROTECTOR PREMIER Now that you have an understanding of

Page 27

Chapter 6: Maintaining Your Protector Premier Product Service 1-800-522-7658 29 Original instructions  Lors de l'entretien sur n'importe

Page 28

Chapter 6: Maintaining Your Protector Premier Product Service 1-800-522-7658 30 Original instructions  Les déflecteurs de hotte devraient être cont

Page 29 - USING YOUR PROTECTOR

Product Service 1-800-522-7658 31 Original instructions CHAPTER 7 MODIFYING YOUR PROTECTOR PREMIER There are several ways to modify the fum

Page 30 - Operating the Lights

Chapter 7: Modifying Your Protector Premier Product Service 1-800-522-7658 32 Original instructions Installing Ceiling Enclosures Above the Fume Hood

Page 31

Chapter 7: Modifying Your Protector Premier Product Service 1-800-522-7658 33 Original instructions Installing Guardian™ Digital Airflow Monitor or

Page 32 - PROTECTOR PREMIER

Chapter 7: Modifying Your Protector Premier Product Service 1-800-522-7658 34 Original instructions Installing an Electrical Duplex Outlet Your Prote

Page 33 - Routine Maintenance Schedule

Product Service 1-800-522-7658 35 Original instructions CHAPTER 8 TROUBLESHOOTING Refer to the following table if your fume hood fails to op

Page 34 - Routine Service Operations

CHAPTER 5: USING YOUR PROTECTOR PREMIER 25 Operating the Vertical Rising Sash 25 Operating the A-Style Combination Sash 25 Operatin

Page 35 - PREMIER

Chapter 8: Troubleshooting Product Service 1-800-522-7658 36 Original instructions PROBLEM CAUSE CORRECTIVE ACTION Fume hood blower operates but l

Page 36 - Fume Hood

Chapter 8: Troubleshooting Product Service 1-800-522-7658 37 Original instructions PROBLEM CAUSE CORRECTIVE ACTION Vertical sash frame is distorted.

Page 37

Product Service 1-800-522-7658 38 Original instructions APPENDIX A PROTECTOR PREMIER COMPONENTS Illustration A-1 indicate the location of the foll

Page 38

Appendix A: Protector Premier Components Product Service 1-800-522-7658 39 Original instructions Item Quantity Part No. Description 10A 1 1302301 Sw

Page 39 - TROUBLESHOOTING

Appendix A: Protector Premier Components Product Service 1-800-522-7658 40 Original instructions Figure A-1

Page 40

Product Service 1-800-522-7658 41 Original instructions APPENDIX B PROTECTOR PREMIER DIMENSIONS Figure B-1 Premier Model Widths 4' 5&a

Page 41

Appendix B: Protector Premier Dimensions Product Service 1-800-522-7658 42 Original instructions Figure B-2 Premier Integral Model Widths

Page 42 - PROTECTOR PREMIER COMPONENTS

Product Service 1-800-522-7658 43 Original instructions APPENDIX C PROTECTOR PREMIER SPECIFICATIONS Environmental Conditions  Indoor use only.

Page 43

Appendix C: Protector Premier Specifications Product Service 1-800-522-7658 44 Original instructions

Page 44

Appendix C: Protector Premier Specifications Product Service 1-800-522-7658 45 Original instructions

Page 45 - PROTECTOR PREMIER DIMENSIONS

Product Service 1-800-522-7658 1 Original instructions CHAPTER 1 INTRODUCTION Congratulations on your purchase of a Labconco Protector® Premie

Page 46

Product Service 1-800-522-7658 46 Original instructions APPENDIX D SERIAL NUMBER TAG DESCRIPTION Serial tag includes standard information with th

Page 47 - SPECIFICATIONS

Appendix D: References Product Service 1-800-522-7658 47 Original instructions D: This fume hood includes three additional electrical receptacles, i

Page 48

Appendix D: Serial Number Tag Description Product Service 1-800-522-7658 48 Original instructions M: This fume hood includes three additional electr

Page 49

Appendix D: References Product Service 1-800-522-7658 49 Original instructions ANNEXE D DESCRIPTION DE SÉRIE TAG NUMBER Étiquette de série comprend

Page 50 - DESCRIPTION

Appendix D: Serial Number Tag Description Product Service 1-800-522-7658 50 Original instructions E: Cette hotte comprend quatre autres prises élec

Page 51

Appendix D: References Product Service 1-800-522-7658 51 Original instructions branché sur un circuit dédié classé au 10A ou les duplex peuvent être

Page 52

Product Service 1-800-522-7658 52 Original instructions APPENDIX E REFERENCES Many excellent reference texts and booklets are currently availab

Page 53 - ANNEXE D

Appendix E: References Product Service 1-800-522-7658 53 Original instructions ANSI Z9.5-2011 Laboratory Standard Covers entire laboratory ventilatio

Page 54

Appendix E: References Product Service 1-800-522-7658 54 Original instructions Department of Labor, Occupational Safety and Health Administration, 29

Page 55 - Appendix D: References

Product Service 1-800-522-7658 55 Original instructions

Page 56 - REFERENCES

Chapter 1: Introduction Product Service 1-800-522-7658 2 Original instructions About This Manual This manual is designed to help you learn how to in

Page 57 - Appendix E: References

Chapter 1: Introduction Product Service 1-800-522-7658 3 Original instructions Typographical Conventions Recognizing the following typographical con

Page 58

Chapter 1: Introduction Product Service 1-800-522-7658 4 Original instructions  CAUTION – See Manual. When this symbol is on a fume hood it indica

Page 59

Product Service 1-800-522-7658 5 Original instructions CHAPTER 2 PREREQUISITES Before you install your laboratory fume hood, you need to